Technical support

Fault Finding Guide

Work through a few focused questions to identify the likely cause and find the relevant technical guidance.

Prefer to talk?020 8870 8635
Choose the closest answerReader wiring faulty
PinNet fob system Fobs All fobs No response when presenting fob to a reader Reader wiring faulty
Recommended guidancePinNet fob system

What to check

The DC voltage between terminals 1 and 2 on the reader should be about 12v. 

Corrective Action

Check PinNet controller power voltage and reader L1-L6 connections

If the reader is a significant distance from the controller there may well be voltage drop and this can be solved by doubling up using spare conductors.

L1    +12v DC
L2    -12v DC
L3    TX data L2 --- L3 0.5v AC
L4    TX data L2 --- L4 8.7v AC
L5    RX data L2 --- L5 2.0v AC
L6    RX data L2 --- L6 5.8v AC

Links

https://www.entryphone.co.uk/pdf/PinNetManualV5.pdf


ID13533