What to check
If neither the red LED is on or the green LED reacts to a fob being presented it is possible that the fob reader has
failed.
Corrective Action
Check the L1-L6 terminals at both the reader and control unit.
To prove it's not a wiring fault, wire the reader on a short piece of cable directly to the PinNet controller.
To check that the port on the PinNet controller is not at fault, wire the reader into a different port.
PinNet reader data voltages at idle. Voltages are approximate and give different readings on AC & DC, see list.
L1 +12v DC
L2 -12v DC
L3 TX data L2 --- L3 0.5v AC
L4 TX data L2 --- L4 8.7v AC
L5 RX data L2 --- L5 2.0v AC
L6 RX data L2 --- L6 5.8v AC