Locks, Releases and Coded access keypads Coded access keypads Rectangular metal buttons Coded Access version 8 (CA8) Master code lost
Recommended guidanceLocks, Releases and Coded access keypads

What to check

On the back of the unit there is a jumper without pins linked, on CA8 it is between the relays bottom centre.

Corrective Action

Master code by-pass pins

1 Short pins together for more than 2 seconds to enter programming mode

2 Check front of unit that Yellow LED is ON

3 Reprogram Master PIN and any others needed whilst in programming mode,

4 press # to exit programming mode, Yellow LED goes Out

5 Test.

Links