What to check
When a video telephone is called from the door panel or the phone "ON" button is pressed, a gnd pulse is sent on the
"SIG" wire to start the central power supply timer, which then supplies 20v to video distributors and the monitors
for about 1 minute. During that timed period, the lamp above the door unit camera will be illuminated.
To test at the monitor, press ON and then measure for DC voltage
between "20v" and "-".
If there is a fault with the monitor not sending the pulse down the "SIG" wire to start the timer, you can manually
simulate this by shorting "SIG" to "-" and pressing "ON" to turn the screen on.
Check the SIG wire at the telephone you should have about 12v DC voltage between "SIG" and "-".
Corrective
Action
Use spare conductor as required or rewire.
Additional notes
Beware of tucking excess unsheathed coax behind the 900-VS4 PCB as this causes shorts on the pcb tracks.